(153689 products)
Lenz
Lenz 25150 Tastenmodul LW150
LENZ 25150
Lenz
Block section module for reverse loops BM3KIf you want to lead a block track, which you build with the BM3, through a reverse loop, then you need, in addition to the LK200, of course, a special BM3 module, the BM3K, and of it equal to 2 pieces. The reason lies in the reporting line, which consists only of a wire, which is very convenient in the "normal case". In this special case, however, the potential is reversed by the reverse loop module, so the message via the message line would no longer w
LENZ 22621
Lenz
In the simplest case, the track voltage is fed to the braking section before the signal via the BM1. If the signal is at "Hp 0", the BM1 will create an asymmetry in the otherwise balanced digital voltage detected by GOLD and SILVER series decoders. The result is a gentle deceleration of the train to a stop.If the train comes from the opposite direction, it simply continues, because the asymmetry is detected direction-dependent. If the signal goes back to "Hp 1", the BM1 is bridged by the signal
LENZ 22600
Lenz
The LH01 hand controller is a device for the XpressNet™, enjoy all the advantages of this fast system bus for the Digital plus system. You can of course plug and unplug the LH01 during operation, the last locomotive operated is saved and can be controlled again immediately.The XpressNet also works bi-directionally: you can also call up information from the control system: if you select a new locomotive, for example, its current speed, direction of travel and the status of its functions are adopt
LENZ 21010
Lenz
Components for use with the Lenz digital system.
LENZ 12200
Lenz
LRB08 occupancy and feedback indicator with 8 outputs.The LRB08 has 8 outputs to which eight track sections to be monitored are connected. The microprocessor working in the LRB08 polls the inputs cyclically. If a current flow is detected in the connected track section, this is reported to the LZ100/LZV100/LZV200 during the next query. If the track is free again (current no longer flows), this change is also reported. The 8 signaling inputs have an adjustable delay time. The delay time can be set
LENZ 11230
Lenz
Dual occupancy detector LB101.
LENZ 11210
Lenz
Components for use with the Lenz digital system.
LENZ 11010
Lenz
Lenz 10321-01 Lokdecoder Silver+ 21-polig
LENZ 10321-01
Fleischmann
6-pin plug decoder (MX630N)
FLEI 687403
Faller
Model: HO gauge. Loudspeaker for retrofitting Car System conversion vehicles in conjunction with the analog-digital conversion kit.
FALL 161366
Doehler & Haass
The memory circuit SP16A can be connected to many decoders (not only decoders from D&H) and improves operation even on dirty track sections or routes with unpolarized frogs.The memory circuit SP16A can be operated with all vehicle decoders that have connection options for supply voltage and ground. It can be used for all data formats that the vehicle decoder supports.Little space requirement and particularly low overall heightThanks to the integrated inductance, it is compatible with asymmetrica
DOEH SP16A
Doehler & Haass
Energy storage device SP05A-2 for SUSI with connection cable for SUSI and with shrink tubingEnergy storage for SUSIDimensions [mm] (with shrink tube) 28.5 * 9.5 * 12.0Stored energy 7.29 WsCapacitor voltage 5.4 VCapacitance 0.5 FBuffer voltage 10.5 VMax. Driving voltage 30 VProduct features and functionsOperation on all locomotive / vehicle decoders with a standard SUSI interfaceAdjustable start of the charging process either according to time or on arrivalAdjustable maximum buffer time so that d
DOEH SP05A-2
Doehler & Haass
Decoder with wires, 1A.
DOEH PD12A-3
Doehler & Haass
PD12A-0 vehicle decoder DCC without connection cable, without connector.Operating mode DCC, DC analogDimensions [mm] 24.2 * 11.0 * 2.4Total load capacity 1.0 AMax motor current 1.0AMax. driving voltage 30 V2 light outputs, each dimmable 150 mA2 additional outputs, dimmable 300 mA eachFor optional operation with a conventional direct current driving device or according to the NMRA standard (DCC)Switching between analog and digital operation is automaticDCC Short addresses (1-127), long addresses
DOEH PD12A-0
Doehler & Haass
A new Doehler & Haass decoder developed exclusively for Modellbahn Union. Two small capacitors are installed on the decoder for driving without data loss. Both the software and the chip itself correspond to the same modern technology as the latest decoders from Doehler & Haass. The decoder, produced in Germany, can be used for both normal DC motors and coreless motors. Switching from analogue to digital operation takes place automatically.The vehicle decoders support braking with asymmetrical di
DOEH PD10MU-3
Doehler & Haass
Doehler & Haass N18-G-2 connection adapter Next18 large with connection cable NEM 652 and with 2 connection strands, length approx. 145 mm.Dimensions [mm] 14.3 * 10.2 * 2.0
DOEH N18-G-2
Doehler & Haass
Doehler & Haass M21-3 Connection adapter 21-pin interface with 11 connection wires, length approx. 145 mm.Dimensions [mm] (without pins) 15.0 * 16.0 * 0.6Dimensions [mm] (with pins) 15.0 * 16.0 * 6.7
DOEH M21-3
Doehler & Haass
Dimensions [mm] 14.0 * 12.0 * 5.5, impedance 8 ohms, max. power 0.8 W, no sound box required.Installation recommendations:In general, the recommendation is to install the loudspeakers far away from the engine in order to:to avoid inadmissible heating of the loudspeakers andto protect the loudspeaker magnets from demagnetization by the sometimes very strong motor magnets (e.g. Roco).Please note the installation recommendations for the LS1308 speaker:One side of the speaker is the membrane (silver
DOEH LS1412S
Doehler & Haass
Dimensions [mm] 15 * 11 * 4.1, impedance 6 ohms, max. power 1.2 W.Installation recommendations:In general, the recommendation is to install the loudspeakers far away from the engine in order to:to avoid inadmissible heating of the loudspeakers and to protect the loudspeaker magnets from demagnetization by the sometimes very strong motor magnets (e.g. Roco).Please note our installation recommendations for the loudspeaker LS1115 or LS1511:One side of the speaker is the membrane (silver finish) sur
DOEH LS1115S
Doehler & Haass
Dimensions [mm] 15 * 11 * 3.5, impedance 6 ohms, max. power 1.2 W.Installation recommendations:In general, the recommendation is to install the loudspeakers far away from the engine in order to:to avoid inadmissible heating of the loudspeakers and to protect the loudspeaker magnets from demagnetization by the sometimes very strong motor magnets (e.g. Roco).Please note our installation recommendations for the loudspeaker LS1115 or LS1511:One side of the speaker is the membrane (silver finish) sur
DOEH LS1115
Doehler & Haass
Dimensions [mm] 13 * 8.0 * 2.9, impedance 6 ohms, max. power 1.0 W.Installation recommendations:In general, the recommendation is to install the loudspeakers far away from the engine in order to:to avoid inadmissible heating of the loudspeakers and to protect the loudspeaker magnets from demagnetization by the sometimes very strong motor magnets (e.g. Roco).
DOEH LS0813S
Doehler & Haass
Doehler & Haass DH22B-2 Vehicle decoder with ribbon cable NEM 652Operating mode SX1, SX2, DCC, MM, DC analog, AC analogDimensions [mm] (under reserve) 20.7 * 15.8 * 5.2Total load capacity 2.0 AMax motor current 2.0AMax. driving voltage 30 VSwitching voltage with AC-analogue max. 45 V peak = 30 V rms.LV, LR (dimmable) each 150 mAAUX1, AUX2 (dimmable) each 300 mAAUX3, AUX4 each 1.0AAUX5, AUX6 each 1.0AAUX7 1.0AAUX8 unamplifiedwith SUSI interfaceProduct features and functionsFor optional operation
DOEH DH22B-2
Doehler & Haass
Doehler & Haass DH22B-4 vehicle decoder without connection cableOperating mode SX1, SX2, DCC, MM, DC analog, AC analogDimensions [mm] (under reserve) 20.7 * 15.8 * 5.2Total load capacity 2.0 AMax motor current 2.0AMax. driving voltage 30 VSwitching voltage with AC-analogue max. 45 V peak = 30 V rms.LV, LR (dimmable) each 150 mAAUX1, AUX2 (dimmable) each 300 mAAUX3, AUX4 each 1.0AAUX5, AUX6 each 1.0AAUX7 1.0AAUX8 unamplifiedwith SUSI interfaceProduct features and functionsFor optional operation w
DOEH DH22B-0